EMC Chamber
DSD's state-of-the-art EMC chamber provides enhanced development and verification testing of power electronics and electrified propulsion systems.
The EMC chamber is CISPR 25 compliant, semi-anechoic, and is specifically designed for high voltage component testing. Based in Warwickshire (UK), it measures both radiated and conducted emissions and meets automotive and aerospace standards.
EMC Chamber Specifications
Specification
- 144m3 semi-anechoic chamber
- 6m x 6m x 4m
- 400V, 63A AC filter
- 1000V, 400A DC filter
- In-cell liquid cooling
- Remote camera viewing
Standards
- Built to CISPR25
- Conforms with BS EN 50147
- IEC 61000-4-2 & ISO TR 10605 compliant
SAC specification
- Semi-anechoic chamber
- 6 x 6 x 4 m external
- 4.75 x 4.75 m internal (absorber tips)
- 18 GHz absorber
- 150 kg 3.5 x 1.5 x 0.9 m ground plane
- 500 kg/m2 floor loading
- 3 phase AC mains filter
- 1000 V 400 A DC supply
- Connections for external coolant
- EN 50147-1 shielding effectiveness
- CISPR 25 annex J long wire method approval and additional site attenuation to 6 GHz
Equipment specification
- Rohde & Schwarz ESW8 test receiver
- R&S antennas:
- FH2-Z6E rod
- HK116E biconical
- HL223 log periodic
- HF907 double rigid waveguide horn
- LISN’s:
- CISPR 25 32A
- CISPR 25 200A
- CISPR 25 400 A
- R&S Elektra emissions software
- Tekbox current probe
- Schwarzbeck BBV 9744 preamplifier
- MK messtechnik CAN FD optical transceivers
- 2 x Cinergia B2C-80 DC converter
- Cinergia GE-30 AC grid emulator
- DC electronic loads
- Range of low-voltage and high-voltage power supplies
To learn more about how DSD approaches development and testing, check out our Facilities page: